Regulations (Standards - 29 CFR)
Nonionizing radiation. - 1926.54

Regulations (Standards - 29 CFR) - Table of Contents Regulations (Standards - 29 CFR) - Table of Contents
• Part Number: 1926
• Part Title: Safety and Health Regulations for Construction
• Subpart: D
• Subpart Title: Occupational Health and Environmental Controls
• Standard Number: 1926.54
• Title: Nonionizing radiation.
• Applicable Standards: 1910.97(a)(3)

1926.54(a)

Only qualified and trained employees shall be assigned to install, adjust, and operate laser equipment.

1926.54(b)

Proof of qualification of the laser equipment operator shall be available and in possession of the operator at all times.

1926.54(c)

Employees, when working in areas in which a potential exposure to direct or reflected laser light greater than 0.005 watts (5 milliwatts) exists, shall be provided with antilaser eye protection devices as specified in Subpart E of this part.

1926.54(d)

Areas in which lasers are used shall be posted with standard laser warning placards.

1926.54(e)

Beam shutters or caps shall be utilized, or the laser turned off, when laser transmission is not actually required. When the laser is left unattended for a substantial period of time, such as during lunch hour, overnight, or at change of shifts, the laser shall be turned off.

1926.54(f)

Only mechanical or electronic means shall be used as a detector for guiding the internal alignment of the laser.

..1926.54(g)

1926.54(g)

The laser beam shall not be directed at employees.

1926.54(h)

When it is raining or snowing, or when there is dust or fog in the air, the operation of laser systems shall be prohibited where practicable; in any event, employees shall be kept out of range of the area of source and target during such weather conditions.

1926.54(i)

Laser equipment shall bear a label to indicate maximum output.

1926.54(j)

Employees shall not be exposed to light intensities above:

1926.54(j)(1)

Direct staring: 1 micro-watt per square centimeter;

1926.54(j)(2)

Incidental observing: 1 milliwatt per square centimeter;

1926.54(j)(3)

Diffused reflected light: 2 1/2 watts per square centimeter.

1926.54(k)

Laser unit in operation should be set up above the heads of the employees, when possible.

1926.54(l)

Employees shall not be exposed to microwave power densities in excess of 10 milliwatts per square centimeter.


Next Standard (1926.55) Next Standard (1926.55)

Regulations (Standards - 29 CFR) - Table of Contents Regulations (Standards - 29 CFR) - Table of Contents



Back to Top Back to Top www.osha.gov www.dol.gov

Freedom of Information Act |These pages are mirrored from the Occupational Safety and Health Administration General Construction Standards pages as reference links for their content in the live reporting of safety violations on active building sites by BuilderWerks users.
Courtesy of IntoText Corporation 813-968-2972 |8708 N Lynn Ave | Tampa FL 33604 |
Occupational Safety & Health Administration
200 Constitution Avenue, NW
Washington, DC 20210