Regulations (Standards - 29 CFR)
Selection of Protective Systems - 1926 Subpart P App F |
Regulations (Standards - 29 CFR) - Table of Contents |
Part Number: | 1926 |
Part Title: | Safety and Health Regulations for Construction |
Subpart: | P |
Subpart Title: | Excavations |
Standard Number: | 1926 Subpart P App F |
Title: | Selection of Protective Systems |
The following figures are a graphic summary of the requirements contained in subpart P for excavations 20 feet or less in depth. Protective systems for use in excavations more than 20 feet in depth must be designed by a registered professional engineer in accordance with 1926.652(b) and (c). _________________________ | | | Is the excavation more | | than 5 feet in depth? | |_________________________| | | ____________________ | ___________________ | | NO | YES | | | Is there potential |_________|__________| Is the excavation | | for cave-in? | | entirely in | |____________________| | stable rock? | | |___________________| | | | ________________________ | | NO | | YES | |___________| Excavation may be made |__________| | | with vertical sides. | | | |________________________| | | | | | | ________________________ | | YES | | NO | |___________| Excavation must be |__________| | sloped, shored, or | | shielded. | |________________________| | Sloping | Shoring or shielding ______________________|________________________ | selected. selected. | | | ______|_________ _________|______ | | | | | Go to Figure 2 | | Go to Figure 3 | |________________| |________________| FIGURE 1 - PRELIMINARY DECISIONS _________________________ | | | Sloping selected as the | | method of protection | |_________________________| | | ___________|______________ | | | Will soil classification | | be made in accordance | | with Sec. 1926.652(b)? | |__________________________| | | YES | NO ______________________|______________________ | | | | ________|____________________ _________________|________ | | | | | Excavation must comply with | | Excavations must comply | | one of the following three | | with Sec. 1926.652(b)(1) | | options: | | which requires a slope | |_____________________________| | of 1 1/2 H:1V (34 deg.). | | | |__________________________| | Option 1: | | | | Sec. 1926.652(b)(3) which | | requires Appendices A | | and B to be followed | | | | | | Option 2: | | | | Sec. 1926.652(b)(3) which | | requires other tabulated | FIGURE 2 - SLOPING OPTIONS | data (see definition to | | be followed. | | | | | | Option 3: | | | | Sec. 1926.652(b)(4) which | | requires the excavation to | | be designed by a registered | | professional engineer. | |_____________________________| ____________________________________ | | | Shoring or shielding selected | | as the method of protection. | |____________________________________| | | _______________|____________________ | | | Soil Classification is required | | when shoring or shielding is | | used. The excavation must comply | | with one of the following four | | options: | |____________________________________| | | | Option 1 | | | | Sec. 1926.652(c)(1) which requires | | Appendices A and C to be followed | | (e.g. timber shoring). | | | | | | Option 2 | | | | Sec. 1926.652(c)(2) which requires | | manufacturers data to be followed | | (e.g. hydraulic shoring, trench | | jacks, air shores, shields). | | | | | | Option 3 | | | | Sec. 1926.652(c)(3) which requires | | tabulated data (see definition) to | | be followed (e.g. any system as | | per the tabulated data). | | | | | | Option 4 | | | | Sec. 1926.652(c)(4) which requires | | the excavation to be designed by a | | registered professional engineer | | (e.g. any designed system). | |____________________________________| FIGURE 3 - SHORING AND SHIELDING OPTIONS |
Next Standard (1926 Subpart Q) |
Regulations (Standards - 29 CFR) - Table of Contents |
Back to Top | www.osha.gov | www.dol.gov |
Freedom of Information Act |These pages are mirrored from the Occupational Safety and Health Administration General Construction Standards pages as reference links for their content in the live reporting of safety violations on active building sites by BuilderWerks users. Courtesy of IntoText Corporation 813-968-2972 |8708 N Lynn Ave | Tampa FL 33604 | |
||
Occupational Safety & Health Administration 200 Constitution Avenue, NW Washington, DC 20210 |